About ten settings decide how an occlusal splint fits, how strong it is and how comfortable it feels. NexorCAD’s factory values are the founder’s own, used on his own cases; most labs never need to change them. Each setting can be changed for the whole workspace, or for one case on the order form.

Setting Step What it does Factory value
Opening (target clearance) Articulator The space between the arches the splint is built into, measured mesh to mesh. 2.5 mm
Retention Blockout The undercut deliberately left unfilled so the splint grips. At 0, every undercut is filled and the splint drops off. 0.10 mm
Draft angle Blockout The taper given to filled walls, so the splint releases along the path of insertion. 1.6°
Path of insertion Blockout The direction the splint goes on: occlusal or anterior. Occlusal
Minimum thickness Generate The thinnest the splint may be. A red shell marks any area that is too thin. 1.8 mm
Posterior clearance Generate The gap left under the posterior cusps in centric. 0.02 mm (20 µm)
Canine contact Generate Both canines in centric, pin in. Below 0 they sit into the splint: −0.15 is a strong contact the jaw rests on. −0.15 mm
Incisor contact Generate The incisors in centric. At −0.07, an 8 µm paper pulls through with slight friction. −0.07 mm
Protrusive and lateral guidance Generate The slope of the guide table; at 0 the table is flat. Ramps bring the guiding teeth down to the occlusal plane. 8°, ramps on
Fit offset Finish The target gap between the fitting surface and the model. Larger seats more easily and holds less. 0.07 mm
Label Finish The text written into the splint, such as the patient’s first name. First name, 2.6 mm high

Settings that work together

  • Retention and fit offset together decide whether a splint is too tight or too loose. A splint that binds on insertion needs less retention or more offset; a splint that falls off needs the opposite. Change one of the two at a time.
  • Opening and minimum thickness: the splint cannot be thicker than the space the opening gives it. If the red shell keeps appearing in the same place, look at the opening before raising the thickness.
  • Canine and incisor contact decide where the jaw rests in centric: mostly on the canines, more lightly on the incisors, never on the posteriors.

On the splint itself

The posteriors never touch, in any movement. From 1 to 8 mm of travel, only the working canine touches in lateral excursion, and only the incisors in protrusion.

Where NexorCAD helps

These settings belong to the workspace: the whole team designs with the same values, on any computer.

  • The factory values are our founder’s own, used on his own cases.
  • You change them once for the whole workspace, or for a single case on the order form.
  • The blockout, the occlusal table and the thickness are calculated from these values, instead of being made by hand or checked by eye as in installed desktop CAD.
  • Everyone works on the current version: no update to install computer by computer.

These guides are written for dentists and dental labs. They do not replace the dentist’s examination and judgment; the dentist decides whether an occlusal splint is indicated.

Design your next Aubé™ splint in NexorCAD

From the two intraoral scans to a print-ready STL, in nine steps. Free for 14 days with 75 credits, enough for three splints.

No credit card. Creating an account takes about two minutes.