At the chair

What to do when a patient breaks their occlusal splint

A splint that breaks more than once means too much force in the wrong place: anterior contacts, the dual splint, material and thickness.

making Aubé™ splints since 20222 min read

In this guide5 sections
  1. Anterior contacts
  2. The dual splint with anterior contacts
  3. Material and thickness
  4. Conclusion
  5. Where NexorCAD helps

When a patient breaks their splint, you remake it, and you ask why it broke. A splint that breaks more than once almost always means too much force in the wrong place, and the design can correct that.

Anterior contacts

One of the most effective ways to reduce the risk of fracture is to design the splint with anterior contacts only. This limits the powerful forces on the splint, which greatly reduces the risk of fracture. It is a key prevention strategy, built on a good understanding of occlusal dynamics.

The dual splint with anterior contacts

For the hardest cases, the dual splint with anterior contacts removes any chance of posterior contact. It is an almost foolproof answer to repeated fractures. See When to make a dual splint with anterior contacts.

Material and thickness

A suitable hard material and enough thickness matter too. A thin area gives way first: check the minimum thickness in the design before reprinting. See What is the best material for an occlusal splint? and Occlusal splint design parameters explained.

Conclusion

Managing fractures takes a complete approach: prevention through design, the choice of material, and options like the dual splint with anterior contacts. To learn more about occlusion and splint management, Dr. Aubé’s course is an invaluable resource: ico-institut.ca.

Where NexorCAD helps

A thin area is the first to give way. NexorCAD shows it before the splint is printed.

  • The minimum thickness is measured from the blockout wax, and thinner areas show in red. In installed desktop CAD it is checked by eye.
  • The case and its files stay in your workspace: a broken splint is reprinted without designing it again.
  • The default design keeps the posteriors out of contact, which takes the most powerful forces off the splint.

These guides are written for dentists and dental labs. They do not replace the dentist’s examination and judgment; the dentist decides whether an occlusal splint is indicated.

Design your next Aubé™ splint in NexorCAD

From the two intraoral scans to a print-ready STL, in nine steps. Free for 14 days with 75 credits, enough for three splints.

No credit card. Creating an account takes about two minutes.